{"id":31892,"date":"2020-03-20T08:58:05","date_gmt":"2020-03-20T01:58:05","guid":{"rendered":"http:\/\/hiconmne.vn\/en\/?p=31892"},"modified":"2020-03-21T20:43:29","modified_gmt":"2020-03-21T13:43:29","slug":"hydrotechnic-hydraulic-siphonic-calculation-program","status":"publish","type":"post","link":"https:\/\/hiconmne.vn\/en\/hydrotechnic-hydraulic-siphonic-calculation-program\/","title":{"rendered":"HYDROTECHNIC HYDRAULIC SIPHONIC CALCULATION PROGRAM"},"content":{"rendered":"<p><strong><a title=\"Link to HydroTechnic Log-in\" href=\"http:\/\/www.hydrotechnic.net\/\">HydroTechnic<\/a><\/strong>\u00a0is our advanced and extremely accurate analytical design calculation program.<\/p>\n<p>We have invested to make HydroTechnic readily accessible as a web based application whereby all users are using the latest version.<\/p>\n<p>Additionally,\u00a0being web-based allows registered users to access on any internet linked computer anywhere in the world and enables our\u00a0<a title=\"e-mail our Technical Department\" href=\"mailto:technical@hydromax.com\" target=\"_blank\" rel=\"noopener\">Technical Support<\/a>\u00a0to assist with any queries.<\/p>\n<p>Having been independently tested by\u00a0<a title=\"Link to HR Wallingford\" href=\"http:\/\/www.hrwallingford.com\/site\/\" target=\"_blank\" rel=\"noopener\">HR Wallingford<\/a>\u00a0(Formerly Hydraulics Research Wallingford), HydroTehnic \u00a0offers extreme precision (testing by CRM confirmed HydroTechnic provided unsurpassed accuracy)\u00a0through reporting of extreme hydraulic conditions (where most competitors report average conditions).<\/p>\n<p>You can always rest assured that the HydroTechnic hydraulic calculations will result in a successful siphonic drainage system when the pipe system is installed to the Hydrotechnic design.<\/p>\n<p><strong>Our 100% success rate is testament to our esteemed position.<\/strong><\/p>\n<p>HydroTechnic allows users to select their chosen\u00a0units of measurement\u00a0to draw, design and calculate in either metric or imperial (&#8220;English&#8221;) feet and inches.<\/p>\n<p>After the Design Engineer has determined design rainfall rate and calculated roof areas, they should determine roof drain positions and volume of water per drain to be drained. From this point the design engineer will design the pipe routes required and draw these pipe routes into HydroTechnic.<\/p>\n<p>HydroTechnic shall then be used to calculate the pipe diameters required to meet the hydraulic requirements of the chosen local design standard or code (the most advanced standards such as BS 8490:2007 or ASPE Technical Design Standard 45 are most commonly used).<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"HydroTechnic Drawing Page - Metric\" src=\"http:\/\/www.hydromax.com\/cms\/images\/screen_shots\/web_hydrotechnic_metric_drawing_view.jpg\" alt=\"HydroTechnic Drawing Page - Metric\" width=\"450\" height=\"270\" \/><img loading=\"lazy\" decoding=\"async\" class=\"\" title=\"HydroTechnic Drawing Page - Imperial\" src=\"http:\/\/www.hydromax.com\/cms\/images\/screen_shots\/web_hydrotechnic_us_drawing_view.jpg\" alt=\"HydroTechnic Drawing Page - Imperial\" width=\"473\" height=\"269\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>The results are displayed as Previous calculation and Current calculation so that the Designer can see the changes being made are moving the right direction to find the solution required.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"HydroTechnic Hydraulic Calculation Summary - metric\" src=\"http:\/\/www.hydromax.com\/cms\/images\/screen_shots\/si_pass-fail.jpg\" alt=\"HydroTechnic Hydraulic Calculation Summary - metric\" width=\"250\" height=\"297\" \/><img loading=\"lazy\" decoding=\"async\" title=\"HydroTechnic Hydraulic Calculation Summary - imperial\" src=\"http:\/\/www.hydromax.com\/cms\/images\/screen_shots\/us_pass_-_fail.jpg\" alt=\"HydroTechnic Hydraulic Calculation Summary - imperial\" width=\"262\" height=\"297\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>Within the Data view, the Design Engineer can find all the information needed to solve the hydraulic callculation including Pressure Loss in each section of the pipe system; prssure, velocity in vertical, velocity in horizontal, velocity at discharge, pipe lengths and configuration and flowrates.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" title=\"HydroTechnic Hydraulic Data View - Imperial\" src=\"http:\/\/www.hydromax.com\/cms\/images\/screen_shots\/web_hydrotechnic_us_data_view_ci.jpg\" alt=\"HydroTechnic Hydraulic Data View - Imperial\" width=\"450\" height=\"356\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>HydroTechnic also gives the design engineer the tools to edit pipe systems as will be required to accomodate real-life on-site change requirements.<\/p>\n<p><strong>Additional Features:<\/strong><\/p>\n<p>Program calculation of system Fill (or Prime) time to ensure speedy operation.<\/p>\n<p>Allows calcualtations with suitable pipe materials (as set by local standards) and can have a mix of materials within each calculation<\/p>\n<p>Generation of Bill of Materials\u00a0that can be printed out, printed to PDF or exported to spreadsheets as .csv format file.<\/p>\n<p>Generation of Calculation results that can be printed out, printed to PDF or exported to spreadsheets as .csv format file.<\/p>\n<p>Output of loading to structure for Full bore flow conditions.<\/p>\n<p>Allows calculations for surcharged discharge conditions.<\/p>\n<p>HydroTechnic program automatically generates Pre-fabrication drawings for use with HDPE pipe sytems\u00a0\u00a0to assist on speeding up installation while the program generation provides ultimate accuracy in this process.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>HydroTechnic\u00a0is our advanced and extremely accurate analytical design calculation program. We have invested to make HydroTechnic readily accessible as a web based application whereby all users are using the latest version. Additionally,\u00a0being web-based allows registered users to access on any internet linked computer anywhere in the world and enables our\u00a0Technical Support\u00a0to assist with any queries. Having been independently tested by\u00a0HR Wallingford\u00a0(Formerly Hydraulics Research Wallingford), HydroTehnic \u00a0offers extreme precision (testing by CRM confirmed HydroTechnic provided unsurpassed accuracy)\u00a0through reporting of extreme hydraulic conditions (where most competitors report average conditions). You can always rest assured that the HydroTechnic hydraulic calculations will result in a successful siphonic drainage system when the pipe system is installed to the Hydrotechnic design. Our 100% success rate is testament to our esteemed position. HydroTechnic allows users to select their chosen\u00a0units of measurement\u00a0to draw, design and calculate in either metric or imperial (&#8220;English&#8221;) feet and inches. After the Design Engineer has determined design rainfall rate and calculated roof areas, they should determine roof drain positions and volume of water per drain to be drained. From this point the design engineer will design the pipe routes required and draw these pipe routes into HydroTechnic. HydroTechnic shall then be used to&#8230;<\/p>\n","protected":false},"author":1,"featured_media":31807,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[308],"tags":[],"class_list":["post-31892","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-san-pham-en"],"_links":{"self":[{"href":"https:\/\/hiconmne.vn\/en\/wp-json\/wp\/v2\/posts\/31892","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/hiconmne.vn\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/hiconmne.vn\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/hiconmne.vn\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/hiconmne.vn\/en\/wp-json\/wp\/v2\/comments?post=31892"}],"version-history":[{"count":1,"href":"https:\/\/hiconmne.vn\/en\/wp-json\/wp\/v2\/posts\/31892\/revisions"}],"predecessor-version":[{"id":31893,"href":"https:\/\/hiconmne.vn\/en\/wp-json\/wp\/v2\/posts\/31892\/revisions\/31893"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/hiconmne.vn\/en\/wp-json\/wp\/v2\/media\/31807"}],"wp:attachment":[{"href":"https:\/\/hiconmne.vn\/en\/wp-json\/wp\/v2\/media?parent=31892"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/hiconmne.vn\/en\/wp-json\/wp\/v2\/categories?post=31892"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/hiconmne.vn\/en\/wp-json\/wp\/v2\/tags?post=31892"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}